<ArticleTitle>Motion Reconstruction and Error Analysis for Human Planar Motions using at least One Freely-Placed Passive Marker per Segment</ArticleTitle>
<VernacularTitle>بازسازی و تحلیل خطای حرکات صفحه‌ای بدن انسان با استفاده از حداقل یک مارکر با نصب آزاد روی هر قطعه</VernacularTitle>
			<FirstPage>1</FirstPage>
			<LastPage>11</LastPage>
			<ELocationID EIdType="pii">243488</ELocationID>
			
<ELocationID EIdType="doi">10.22041/ijbme.2021.128760.1599</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>فاطمه</FirstName>
					<LastName>اکبری‌فر</LastName>
<Affiliation>دانشجوی کارشناسی ارشد، دانشکده‌ی مهندسی مکانیک، دانشگاه یزد، یزد، ایران</Affiliation>

</Author>
<Author>
					<FirstName>محمدهادی</FirstName>
					<LastName>هنرور</LastName>
<Affiliation>استادیار، دانشکده‌ی مهندسی مکانیک / هسته‌ی علمی سامانه‌های پشتیبان در توسعه‌ی سلامت، دانشگاه یزد، یزد، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-4464-7194</Identifier>

</Author>
<Author>
					<FirstName>مصطفی</FirstName>
					<LastName>حاج‌لطفعلیان</LastName>
<Affiliation>دکتری بیومکانیک ورزش، هسته‌ی علمی سامانه‌های پشتیبان در توسعه‌ی سلامت ، دانشگاه یزد، یزد، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-9581-5645</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2020</Year>
					<Month>06</Month>
					<Day>07</Day>
				</PubDate>
			</History>
		    <Abstract>Finding the center of rotation (COR) is needed for defining the anatomical axis of the skeletal system and for the kinematic calculation of joints in biomechanical studies. For this purpose, predictive and functional methods can be used. In the predictive methods, regression equations obtained from anthropometric measurements are used, and in the functional methods, the relative motion of the two adjacent segments is used to find COR. The purpose of this study is to formulate the circle fitting algorithm as a functional method with two analytical and optimization solutions. In order to evaluate the algorithm, error analysis was performed by both analytical and numerical methods. Also, effective factors in error estimating of COR position such as standard deviation of measurement system error (σ), rotation angle (α) and the distance between marker and COR (r), was evaluated. The results showed a high correlation (r=0.99) between analytical and numerical solution, which proved the accuracy of the error analysis. In this study, optimization method according to the accuracy of better estimates in low quantities α, less influence on high quantities σ and high speed in problem solving, can be taken into consideration to reconstruct human movements in biomechanical studies. Use of functional methods, eliminates the need for attaching markers to anatomical landmarks and provides a new development in motion data acquisition.</Abstract>
			<OtherAbstract Language="FA">یافتن موقعیت مرکز دوران برای تعریف محور آناتومیکی سیستم اسکلتی و در مطالعات بیومکانیکی برای محاسبه­ی کینماتیک مفاصل ضروری است. برای این منظور می­توان از روش­های پیش­بین و عمل‌کردی استفاده کرد. در روش­های پیش­بین از معادلات رگرسیونی حاصل از اندازه­گیری­های آنتروپومتریکی و در روش­های عمل‌کردی از حرکت نسبی اندام­های مجاور مفصل برای یافتن مرکز آنی دوران استفاده می­شود.­ هدف از این مطالعه فرموله کردن الگوریتم برازش دایره به عنوان روشی عملیاتی با دو روش حل تحلیلی و بهینه­سازی است. به منظور ارزیابی الگوریتم، تحلیل خطا به دو روش تحلیلی و عددی انجام شده و عوامل موثر در خطای تخمین موقعیت مرکز دوران مانند انحراف از معیار خطای سیستم داده­برداری (σ)، زاویه­ی دوران (α) و فاصله‌ی نشان­گر از مرکز دوران (r) مورد بررسی قرار گرفته است. نتایج حاکی از وجود همبستگی بالا (99/0=r) بین دو روش حل تحلیلی و عددی بوده که صحت تحلیل خطا را اثبات کرده است. از بین دو روش حل تحلیلی و بهینه­سازی که در این مطالعه بررسی شده است، روش بهینه­سازی با توجه به دقت تخمین مطلوب­تر در مقادیر پایین α، تاثیرپذیری کم‌تر در مقادیر بالای σ و سرعت بالا در حل مساله، می­تواند در مطالعات بیومکانیکی برای بازسازی حرکات انسان مورد توجه قرار گیرد. با گسترش استفاده از روش­های عمل‌کردی می­توان نیاز به مارکرگذاری نشانه­های آناتومیکی را از بین برد و زمینه­ساز تحولی جدید در داده­برداری حرکتی ­شد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">بازسازی حرکت</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مرکز دوران</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">برازش دایره</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">تحلیل امید ریاضی خطا</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.ijbme.org/article_243488_b5191679b26d0202c9b0221ae88599d5.pdf</ArchiveCopySource>
</Article>
</ArticleSet>