[1] Berquist TH; Imaging atlas of orthopaedic appliances; Raven Press, New York, 1995.
[2] Yahiro MA; Comprehensive literature review; Pedicle screw fixation devices; Spine 1994; 19: S2297-2299.
[3] Yuan HA, Garfin SR, Dickman CA, Mardjetko SM; A historical cohort study of pedicle screw fixation in thoracic lumbar and sacral spinal fusions; Spine 1994; 19: S2279-2296.
[4] Benson DR, Burkus JK, Montesano PX, Sutherland TL, McLain RF; Unstable thoracolumbar and lumbar burst fractures with the AO fixator interne; Journal of Spinal Disease 1992; 5: 335-343.
[5] Carl AL, Tromanhauser SG, Roger DJ; Pedicle screw instrumentation for thoracolumbar burst fractures and fracture dislocations; Spine 1992; 17: S317-S324.
[6] Crutcher, JP, Anderson PA, King HA, Montesano PX; Indirect spinal canal decompression in patients with thoracolumbar burst fractures treated by posterior distraction rods; Journal of Spinal Disease 1991; 4: 39- 48.
[7] Dickman CA, Fessler RG, MacMillan M, Hadid RW, Transpedicular screw-rod fixation of the lumbar spine, Operative technique and outcome in 104 cases; Journal of Neurosurgery 1992; 77: 860-870.
[8] McAfee PC, Weiland DJ; Survivorship analysis of pedicle screw instrumentation; Spine 1991; 16: S422- S427.
[9] Lim TH, Kim JG, Fujiwara A, Yoon TT, Lee SC, Ha JW; Biomechanical evaluation of diagonal fixation in pedicle screw instrumentation; Spine 2001; 26: 2498- 2503.
[10] Chen CS, Cheng CK, Liu CL, A biomechanical comparison of posterolateral fusion and posterior fusion in the lumbar spine; J Spinal Disord Tech. 2002; 15: 53-63.
[11] Liu CL, Chen HH, Cheng CK, Kao HC, Lo WH, Biomechanical evaluation of a new anterior spinal implant; Clin Biomech 1998; 13: S40-S45.
[12] Rohlmann A, Bergmann G, Graichen F; Loads on an internal spinal fixation device during walking; J Biomech 1997; 30: 41 7.
[13] Rohlmann A, Bergmann G, Graichen F; Loads on internal spinal fixators measured in different body positions; Eur. Spine 1999; 8: 354-9.
[14] Yerby SA, Ehteshami McLain RF; Loading of pedicle screw within the vertebra; J. Biomech. 1997; 30: 951- 954.
[15] McKinley TO, McLain RF, Yerby SA, Sharkkey NA, Sarigul-Klijn N, Smith TS; The effect of surgical technique on intravertebral and intrapediclular bending moments; Spine 1999; 24: 18-24.
[16] McKinley TO, McLain RF, Yerby SA, Sarigul-Klijn N, Smith TS; The effect of pedicle morphology on pedicle screw loading; Spine 1997; 22: 246-252.
[17] McKinley TO, McLain RF, Yerby SA, Sharkey NA, Sarigul-Klijn N, Smith TS; Characteristics of pedicle screw loading; Effect of surgical technique on interavertebral and interapedicular bending moments; Spine 1999; 24: 18-24.
[18] Youssef JA, McKinley TO, Yerby SA, McLain RF; Characteristics of pedicle screw loading; Effect of sagittal insertion angle on interapedicular bending moments; Spine 1999; 24: 1077-1081.
[19] McLain RF, McKinley TO, Yerby SA, Sarigul-Klijn N, Smith TS; The effect of bone quality on pedicle screw loading in unstable burst fractures; A synthetic model; Spine 1997; 22: 1454-60.
[20] Goel V, Kim Y, Lim T, Weinstein J; An analytical investigation of spinal instrumentation; Spine 1988; 13: 1003-1010.
[21] Puttlitz CM, Goel VK, Traynelis VC, Clark CA; A finite element investigation of upper cervical instrumentation; Spine 2001; 26: 2449-2455.
[22] Gayet LE, Pries P, Hamcha H, Clarac JP; Biomechanical study and digital modeling of traction resistance in posterior thoracic implants; Spine 2002; 27: 707-714.
[23] Rohlmann A, Calisse J, Bergmann G; Internal spinal fixator Stiffness has only a minor influence on stresses in the adjacent discs; Spine 1999; 24: 1192-6.
[24] Zander T, Rohlmann A, Klockner C, Bergmann G; Effect of bone graft characteristics on the mechanical behavior of the lumbar spine; J Biomech 2002; 35: 491-7.
[25] Farahmand F, Hosseini Nasab H, Karegarnovin MH; A 3-D nonlinear finite element study on the L3-L5 lumbar unit subjected to physiological loads; Proceedings of Engineering Systems Design and Analysis Conference (ESDA 2002); Istanbul; Jul 2002.
[26] Farahmand F, Hosseini Nasab H, Karegarnovin MH; A Finite Element Study of the Effects of Nucleotomy, Proceedings of the BioMed 2002: 189-192, Kuala Lumpur; Jun 2002.
[27] حسینینسب سیدحامد، فرهمند فرزام، کارگرنوین محمدحسین؛ بررسی نقش پارامترهای مکانیکی در ایجاد کمردرد با استفاده از مدلسازی المان محدود جزء حرکتی L3-L4 ستون مهره؛ دهمین کنفرانس سالانه مهندسی مکانیک ایران، 1381.
[28] Rohlmann A, Bergmann G, Graichen F; Placing a bone graft more posteriorly may reduce the risk of pedicle screw breakage; analysis of an unexpected case of pedicle screw breakage; J. Biomech. 1998; 3: 763-7.
[29] White AA, Panjabi MM; Clinical biomechanics of the spine; JB Lippincott; 1990.
[30] Nachemson AL; Disc pressure measurements; Spine 1981; 6: 93-102.