Abstract

In this article a wireless patient monitoring system for vital signs (respiratory rate and heart beat) is presented. The recorded biosignal is the photoplethysmogram using a probe attached to the patient's finger. This signal is amplified, filtered and digitized by an on-board processor unit before finally being sent wirelessly via a transmitter. The capacity of the current system is 16 patients whose data can be received through a common receiver by a central server which measures and displays the heart beat and respiratory rate for each patient on the monitor.

Keywords

[1]     Ivashov S.I. et al., Detection of human breathing and heartbeat by remote radar; Progress in Electromagnetic Research Symposium,Pisa, Italy, 2004; pp. 663–666.
[2]     Mack D.C. et al., Development and preliminary validation of heart rate and breathing rate detection using a passive, ballistocardiography-based sleep monitoring system; IEEE Transactions on Information Technology in Biomedecine, 2009; 13(1): 111-120.
[3]     Zhu X. et al., Real-time monitoring of respiration rhythm and pulse rate during sleep; IEEE Transactions on Biomedical Engineering, 2006; 53(12): 2553-2563.
[4]     Turakhia M.P. et al. Latency of ECG displaysof hospital telemetry systems ascience advisory from the american heart; Circulation., 2012; 126: 1665- 1669.
[5]     Drew B.J. et al., Practice standards for electrocardiographic monitoring in hospital settings; Circulation., 2004; 110: 2721–2746.
[6]     Available: http://www.mayoclinic.com/health/heartrate/ AN01906
[7]     Available: http://www.uihealthcare.com/topics/generalhealth/g hea4577.html
[8]     Dash S. et al., Estimation of respiratory rate from ECG, photoplethysmogram, and piezoelectric pulse transducer signals: a comparative study of timefrequency methods; IEEE Transactions on Bimedical Engineering, 2010; 57(5): 1099-1107.
[9]     Wong K.I., Rapid prototyping of a low-power, wireless, reflectance photoplethysmography system; In Body Sensor Networks (BSN), 2010 International Conference on, pp. 47-51. IEEE, 2010.
[10] Gupta D., Shrestha A., Orlewicz M., What is the role of telemetry in patients with pacemakers?; WebmedCentral Cardiology 2011; 2(6): WMC001975.
[11] Available: http://www.medicareagencies.com/sleep_psg.html
[12] Hu W. et al., An intelligent non-contact wireless monitoring system for vital signs and motion detection; In System Science and Engineering (ICSSE), 2010 International Conference on, pp. 190-194. IEEE, 2010.